{"product_id":"holzvergaserkessel-atmos-dc18gse-19-kw-ohne-automatische-zuendung","title":"ATMOS DC18GSE 19 kW wood gasification boiler","description":"\u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Application Area\u003c\/h2\u003e \u003cp\u003eThe ATMOS DC18GSE is a hand-fed wood gasification boiler with a nominal heat output of 19 kW for central heating of single-family homes and comparable properties. The GSE series combines wood gasification with a ceramic secondary combustion chamber, induced draft fan, and a high-performance flue gas heat exchanger. The standard version operates with electromechanical control and is manually ignited.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eIn the upper filling chamber, the split logs are gasified. The resulting wood gas flows through the nozzle into the ceramic-lined secondary combustion chamber, where it is burned at high temperature. Primary and secondary air can be adjusted separately to adapt combustion to different suitable wood qualities. An induced draft fan supports controlled flue gas extraction. The Belimo actuator limits the flue gas temperature, thereby supporting stable boiler operation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThe induced draft fan supports both ignition and refueling and reduces smoke emission into the boiler room. After complete burn-off, the fan and connected boiler circulation pump can be switched off automatically. The separate primary and secondary air control enables targeted adjustment of combustion, while the ceramic combustion chamber and tubular heat exchanger are designed for high energy utilization.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe DC18GSE is intended for integration into a heating system with an adequately sized buffer tank. A return temperature raising system, for example via Laddomat 22, thermostatic mixing valve, or a correspondingly planned mixing solution, must ensure the required minimum return temperature. Through a professionally designed hydraulic system, the generated heat can be transferred to radiator, underfloor heating, or mixed heating systems, among others.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical Data at a Glance\u003c\/h2\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eNominal heat output\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e19 kW\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFuel\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eDry split logs\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eCombustion technology\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eWood gasification\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eBoiler efficiency\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e91.5%\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eEnergy efficiency class\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eA+\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eEnergy efficiency index EEI\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e118\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eAnnual space heating efficiency\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e81%\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eBoiler class\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMaximum log length\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e330 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eBoiler temperature\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e80–90 °C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e2.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eChimney draft\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e16 Pa\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFlue gas temperature at rated output\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e137.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFlue pipe \/ exhaust duct\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e150\/152 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eHeating connections\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1 1\/2 inch\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eSafety heat exchanger\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eavailable\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eConnection voltage\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e230 V \/ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eRated electrical load\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e50 W\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eProtection class of electrical components\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eDimensions H × W × D\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1281 × 680 × 820 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e376 kg\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eThe boiler is intended for professional installation and commissioning by a qualified heating contractor. The chimney and flue gas path must be matched to the required draft of 16 Pa. The return temperature boost must ensure a minimum return temperature of 65 °C. The thermal drain safety device must be connected according to the system design; electrical work must be carried out by appropriately qualified professionals.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eSufficiently dry split or chopped wood with a moisture content of 12–20% and a diameter of about 80–150 mm is used. The maximum log length of the DC18GSE is 330 mm. This product variant is the standard version with manual ignition; versions with ACD04 and automatic ignition are separate variants.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eATMOS DC18GSE wood gasification boiler\u003c\/li\u003e \u003cli\u003eSteel brush with accessories\u003c\/li\u003e \u003cli\u003ePoker\u003c\/li\u003e \u003cli\u003eFill cock\u003c\/li\u003e \u003cli\u003eOperating and maintenance instructions\u003c\/li\u003e \u003cli\u003eDraft regulator HONEYWELL FR 124\u003c\/li\u003e \u003cli\u003eAsh pan\u003c\/li\u003e \u003cli\u003eDevice for pulling the braking devices out of the flue gas duct\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Atmos","offers":[{"title":"Default Title","offer_id":49424057958748,"sku":"01.04.18","price":5477.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/ATMOS_GSE_Holzvergaserkessel_Frontansicht.jpg?v=1786829555","url":"https:\/\/hr.gemashop.de\/en\/products\/atmos-dc18gse-piroliticki-kotao-na-drva-19kw","provider":"GEMA Shop","version":"1.0","type":"link"}