{"product_id":"atmos-dc22gse-holzvergaserkessel-23kw","title":"ATMOS DC22GSE 23 kW Wood Gasification Boiler Log Boiler","description":"\u003ch2\u003eATMOS DC22GSE Wood Gasification Boiler 23 kW\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eATMOS DC22GSE Wood Gasification Boiler\u003c\/strong\u003e is a modern solid fuel boiler for the efficient combustion of firewood. With a rated heat output of 23 kW, this model is particularly suitable for single-family homes and medium-sized heating systems.\u003c\/p\u003e\n\u003cp\u003eThanks to modern wood gasification technology, the boiler achieves high efficiency levels while maintaining low emissions. The ATMOS DC22GSE meets the requirements of the \u003cstrong\u003eBImSchV Stage II\u003c\/strong\u003e and achieves the \u003cstrong\u003eEnergy Efficiency Class A+\u003c\/strong\u003e. :contentReference[oaicite:3]{index=3}\u003c\/p\u003e\n\u003ch3\u003eHighlights \/ Advantages\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e⭐ Wood gasification boiler with 23 kW output for single-family homes\u003c\/li\u003e\n\u003cli\u003e⭐ Efficiency up to 91.8 % for efficient wood combustion\u003c\/li\u003e\n\u003cli\u003e⭐ Energy Efficiency Class A+ according to EU energy labeling\u003c\/li\u003e\n\u003cli\u003e⭐ Suitable for firewood up to 330 mm in length\u003c\/li\u003e\n\u003cli\u003e⭐ Meets the requirements of BImSchV Stage II\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplication Area \u0026 Target Audience\u003c\/h2\u003e\n\u003cp\u003eThe ATMOS DC22GSE is a manually fed wood gasification boiler for efficient firewood heating systems.\u003c\/p\u003e\n\u003cp\u003eTypical application areas:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHeating systems in single-family homes\u003c\/li\u003e\n\u003cli\u003eRenovation of existing wood heating systems\u003c\/li\u003e\n\u003cli\u003eNew builds with renewable heating technology\u003c\/li\u003e\n\u003cli\u003eHeating systems with buffer storage tanks\u003c\/li\u003e\n\u003cli\u003eHeating systems with radiators or underfloor heating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe boiler is designed for use in modern heating systems and should be installed by a qualified HVAC specialist.\u003c\/p\u003e\n\u003ch2\u003eAdvantages in Everyday Use\u003c\/h2\u003e\n\u003cp\u003eWood gasification boilers utilize the energy of the fuel particularly efficiently. In the ATMOS DC22GSE, the wood is first gasified and then completely combusted at high temperatures.\u003c\/p\u003e\n\u003cp\u003eThis technology enables:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ehigh energy utilization of the fuel\u003c\/li\u003e\n\u003cli\u003ereduced emissions\u003c\/li\u003e\n\u003cli\u003econsistent heat output\u003c\/li\u003e\n\u003cli\u003eeconomical heating operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe generous combustion chamber allows for convenient refilling of firewood and supports longer heating intervals.\u003c\/p\u003e\n\u003ch2\u003eTechnology \u0026 Equipment\u003c\/h2\u003e\n\u003cp\u003eThe wood gasification boiler features a forced-draft fan to support the combustion process and stabilize the chimney draft.\u003c\/p\u003e\n\u003cp\u003eThe most important technical components include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eForced-draft fan\u003c\/li\u003e\n\u003cli\u003eBoiler thermostat\u003c\/li\u003e\n\u003cli\u003eSafety thermostat (STB)\u003c\/li\u003e\n\u003cli\u003eFlue gas thermostat\u003c\/li\u003e\n\u003cli\u003eBelimo actuator\u003c\/li\u003e\n\u003cli\u003eThermal discharge safety device\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDry firewood with a moisture content of approximately 12–20 % is used as fuel.\u003c\/p\u003e\n\u003ch2\u003eEfficiency \u0026 Environment\u003c\/h2\u003e\n\u003cp\u003eThrough wood gasification technology, the ATMOS DC22GSE achieves high energy efficiency while simultaneously reducing emissions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnergy Efficiency Class: A+\u003c\/li\u003e\n\u003cli\u003eBoiler efficiency: up to 91.8 %\u003c\/li\u003e\n\u003cli\u003eComplies with BImSchV Stage II\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis makes the boiler suitable for modern heating systems with renewable fuels.\u003c\/p\u003e\n\u003ch2\u003eCompatibility \u0026 System Integration\u003c\/h2\u003e\n\u003cp\u003eWood gasification boilers are typically combined with buffer storage tanks to efficiently store the generated heat and distribute it within the heating system.\u003c\/p\u003e\n\u003cp\u003eTypical combinations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBuffer storage tanks\u003c\/li\u003e\n\u003cli\u003eReturn temperature elevation\u003c\/li\u003e\n\u003cli\u003eRadiator heating\u003c\/li\u003e\n\u003cli\u003eUnderfloor heating\u003c\/li\u003e\n\u003cli\u003eThermal solar systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Data\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eATMOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDC22GSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eWood Gasification Boiler \/ Solid Fuel Boiler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Heat Output\u003c\/td\u003e\n\u003ctd\u003e23 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUseful Heat Output\u003c\/td\u003e\n\u003ctd\u003e24.2 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e91.8 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Efficiency Class\u003c\/td\u003e\n\u003ctd\u003eA+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eFirewood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Log Length\u003c\/td\u003e\n\u003ctd\u003e330 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustion Chamber Volume\u003c\/td\u003e\n\u003ctd\u003e80 l\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Volume in Boiler\u003c\/td\u003e\n\u003ctd\u003e73 l\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Operating Pressure\u003c\/td\u003e\n\u003ctd\u003e2.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Return Temperature\u003c\/td\u003e\n\u003ctd\u003eminimum 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlue Gas Connection\u003c\/td\u003e\n\u003ctd\u003e150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e1281 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e680 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e820 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e373 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V \/ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level\u003c\/td\u003e\n\u003ctd\u003e65 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eScope of Delivery\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eATMOS DC22GSE Wood Gasification Boiler\u003c\/li\u003e\n\u003cli\u003eForced-draft fan\u003c\/li\u003e\n\u003cli\u003eIntegrated thermostats and safety devices\u003c\/li\u003e\n\u003cli\u003eCleaning cover and maintenance components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAccessories \u0026 System Recommendations\u003c\/h2\u003e\n\u003cp\u003eFor efficient operation, the manufacturer recommends additional system components.\u003c\/p\u003e\n\u003cdiv class=\"cross-sell\"\u003e\n\u003ch3\u003eCompatible System Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/gemashop.de\/collections\/pufferspeicher\"\u003eBuffer storage tanks\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/gemashop.de\/collections\/ruecklaufanhebung\"\u003eReturn temperature elevation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/gemashop.de\/collections\/heizungszubehoer\"\u003eHeating accessories\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eInstallation \u0026 Safety Notes\u003c\/h2\u003e\n\u003cp\u003eThe installation of the wood gasification boiler must be carried out by a qualified heating specialist. Integration into the heating system should be done with a buffer storage tank and return temperature elevation.\u003c\/p\u003e\n\u003cp\u003eThe minimum return temperature of 65 °C specified by the manufacturer must be maintained.\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat is the output of the ATMOS DC22GSE?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe wood gasification boiler has a rated heat output of 23 kW.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhich fuel is used?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe boiler is operated with firewood. Dry wood with 12–20 % residual moisture is recommended.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow long can the logs be?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe maximum log length according to the manufacturer is 330 mm.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat energy efficiency class does the boiler have?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe ATMOS DC22GSE has Energy Efficiency Class A+.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eDoes the boiler meet legal emission requirements?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes, the wood gasification boiler meets the requirements of BImSchV Stage II.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eIs a buffer storage tank necessary?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eWood gasification boilers are typically operated with a buffer storage tank to efficiently store heat and optimize operation.\u003c\/p\u003e\n\u003c\/details\u003e","brand":"Atmos","offers":[{"title":"with automatic ignition ACD 04","offer_id":49424184246620,"sku":"01.04.22-AZ","price":7747.35,"currency_code":"EUR","in_stock":true},{"title":"without","offer_id":49424184181084,"sku":"01.04.22-L","price":6527.01,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/atmos-gse-holzvergaser-25-kw-effizient-heizen-mit-touch-display-2464064.png?v=1770692533","url":"https:\/\/hr.gemashop.de\/en\/products\/atmos-dc22gse-wood-gasification-boiler-23kw","provider":"GEMA Shop","version":"1.0","type":"link"}