Gasherme Vaillant conductor Ecotec Plus VC/VCW/VCI 1-5
Provider:
Vaillant
inkl. MwSt. / zzgl. Versand
Guaranteed safe checkout

Gasherme Vaillant conductor Ecotec Plus VC/VCW/VCI 1-5
Vaillant condensing gas boiler
Gas condensing boiler Vaillant ecoTEC plus VC/VCW/VCI 1-5
The ecoTEC plus VC/VCW/VCI 1-5 is the ideal gas condensing boiler for single-family homes and multi-family buildings. It can also be combined with a heat pump to create a sustainable hybrid system.
Technical data: Vaillant condensing gas boiler
Technical data | Unit | VC 10CS/1 -5 | VC 15CS/1 -5 | VC 20CS/1 -5 | VC 25CS/1 -5 | VC 30CS/1 -5 |
---|---|---|---|---|---|---|
Heating output at 50/30°C natural gas E, natural gas LL (Min - Max) | kW | 3.4 - 10.9 | 3.4 - 16.4 | 3.4 - 21 | 3.4 - 26.4 | 4.5 - 33.3 |
Heating output at 80/60°C natural gas E, natural gas LL (Min - Max) | kW | 3 - 9.9 | 3 - 14.8 | 3 - 19.7 | 3 - 24.7 | Apr 30 |
Heating output at 50/30°C LPG (Min - Max) | kW | 5.4 - 10.9 | 5.4 - 16.4 | 5.4 - 21 | 5.4 - 26.4 | 8.4 - 33.3 |
Heating output at 80/60°C LPG (Min - Max) | kW | 4.8 - 9.9 | 4.8 - 14.8 | 4.8 - 19.7 | 4.8 - 24.7 | 7.8 - 30 |
Heating output in hot water operation Natural Gas E, Natural Gas LL, Liquefied Petroleum Gas (Max) | kW | 20 | 20 | 24 | 27.5 | 34.8 |
Efficiency at 30% according to EN 15502 Natural Gas E, Natural Gas LL, Liquefied Petroleum Gas | % | 109 | 109 | 110 | 109 | 110 |
Efficiency in hot water operation Natural gas E, Natural gas LL, Liquefied petroleum gas | % | 98 | 98 | 98 | 98 | 98 |
Seasonal space heating efficiency ηs | % | 92 | 93 | 94 | 94 | 94 |
Electrical power consumption at 30% | W | 52 | 45 | 41 | 57 | 59 |
Electrical power consumption in heating mode (max) | W | 66 | 56 | 55 | 91 | 80 |
Electrical power consumption in standby | W | 2 | 2 | 2 | 2 | 2 |
Components included in electrical.Performance | pump | |||||
Standby heat loss at tK 70°C | % | 0.91 | 0.61 | 0.45 | 0.36 | 0.3 |
Contents heating side | l | 2.1 | 2.1 | 2.1 | 2.1 | 2.6 |
Max operating pressure on the heating side | bear | 3 | 3 | 3 | 3 | 3 |
Max heating flow temperature | °C | 85 | ||||
Connection value for natural gas E 1) 2) | m³/h | 2.2 | 2.2 | 2.6 | 3 | 3.8 |
Connection value for natural gas LL 1) 2) | m³/h | 2.5 | 2.5 | 3 | 3.5 | 4.4 |
Connection value for liquid gas 1) 2) | kg/h | 0.8 | 0.8 | 1 | 1.1 | 1.5 |
Condensation amount at 50/30°C | l/h | 1.02 | 1.53 | 2.04 | 2.55 | 3.06 |
Pump flow rate at ΔT 20 K (residual head) | l/h (mbar) | 430 (200) | 645 (200) | 849 (200) | 1,075 (200) | 1,290 (200) |
Expansion tank contents | l | 10 | 10 | 10 | 10 | 10 |
form | bear | 0.75 | 0.75 | 0.75 | 0.75 | 0.75 |
Tension | 230V/50Hz | 230V/50Hz | 230V/50Hz | 230V/50Hz | 230V/50Hz | |
Product dimensions (height/width/depth) | mm | 720/440/348 | ||||
Product weight | kg | 34 | 34 | 34 | 34 | 39 |
Heating connection (flow and return) | G 3/4 | G 3/4 | G 3/4 | G 3/4 | G 3/4 | |
Memory connection | G 1/2 | G 1/2 | G 1/2 | G 1/2 | G 1/2 | |
Gas connection | Ø 20 mm | Ø 20 mm | Ø 20 mm | Ø 20 mm | Ø 20 mm | |
Connection air, exhaust | Ø 60/100 | Ø 60/100 | Ø 60/100 | Ø 60/100 | Ø 80/125 | |
CE PIN | 0063CU3910 | 0063CU3910 | 0063CU3910 | 0063CU3910 | 0063CU3910 | |
Gas appliance category | I2N, I3P | I2N, I3P | I2N, I3P | I2N, I3P | I2N, I3P |