{"product_id":"gema-mdc-230-bundle-modul-heizstab-wehp2230-2-0-kw-230-v","title":"GEMA MDC 230 heating module + heating rod WEHP2230 2.0 kW 230 V","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Application Area\u003c\/h2\u003e \u003cp\u003eThe MDC 230 Bundle Module + Heating Rod WEHP2230 combines an MDC 230 heating module for central heating systems with a matching 2.0 kW heating rod for 230 V. The bundle is intended for supplementary heat input into the heating circuit and is aimed at systems where electric supplementary heating is to be integrated cleanly into the existing heating system.\u003c\/p\u003e \u003cp\u003eIt is designed for use in open or closed central heating systems with appropriate safety devices. Typical applications include supplementary heating, frost protection support, emergency heat support, or the use of surplus electricity to add extra heat to the heating circuit.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eThe MDC 230 module forms the hydraulic base body of the bundle. It features a steel tank with 50 mm polyurethane foam thermal insulation, a heating circuit connection with 1 1\/4 inch female thread, and a heating cartridge connection with 1 1\/2 inch female thread.\u003c\/p\u003e \u003cp\u003eThe heating rod WEHP2230 included in the bundle is designed as a 2.0 kW version for 230 V. It is based on the MB 2000 OWR1\/230V design, has a 1 1\/2 inch thread, an installation length of 385 mm, an integrated thermostat, and IP44 protection rating.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThe bundle simplifies selection because the module and heating rod are already listed as a technically matched combination. Operators thus receive a clearly assignable solution for additional heat in the heating circuit without having to coordinate the module and heating cartridge separately.\u003c\/p\u003e \u003cp\u003eThanks to the 230 V version, the bundle is particularly suitable for applications with moderate electric heating output. Temperature control is handled by the heating rod\u0026#39;s integrated thermostat.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe MDC 230 heating module is integrated into the parallel heating circuit on the flow or return line of the main heat source. The module is designed for water or a suitable glycol mixture up to a maximum concentration of 50%.\u003c\/p\u003e \u003cp\u003eFor operation, the minimum flow rate must be ensured. At 2.0 kW heating output, this is 114 l\/h or 1.9 l\/min. An additional circulation pump and a functional safety valve must be included in the system design by the installer.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical data at a glance\u003c\/h2\u003e \u003cp\u003eThe following information refers to the specific bundle consisting of the MDC 230 module and the matching electric heating cartridge WEHP2230.\u003c\/p\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eModel name\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eMDC 230 + WEHP2230\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eBundle type\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eModule + heating rod\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eBase module in the bundle\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eMDC 230\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating rod SKU in the bundle\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eWEHP2230\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eRated power\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e2.0 kW\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePower consumption\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e2,000 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eVoltage\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e230 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating rod connection size\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e1 1\/2 inch \/ 6\/4 inch\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating rod installation length\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e385 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eTemperature range\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eapprox. 20 to 70 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eSafety temperature limiter\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eapprox. 80 to 98 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating rod protection rating\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eIP44\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eModule insulation\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e50 mm polyurethane foam\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMedium\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eWater or suitable glycol mixture up to max. 50% concentration\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMinimum flow rate\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e114 l\/h or 1.9 l\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eModule connection heating circuit\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eFemale thread G 1 1\/4 inch\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating cartridge connection module\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eFemale thread G 1 1\/2 inch\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. operating pressure\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e10 bar \/ 1.0 MPa\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. operating temperature module\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e90 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eModule length\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e500 mm\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eThe hydraulic connection is made in the parallel heating circuit on the flow or return of the main heat source. The pipe routing must allow complete filling and safe venting.\u003c\/p\u003e \u003cp\u003eInstallation, electrical connection, protection, and commissioning are tasks for qualified professionals. Before switching on, the module and system must be completely filled and vented. The additional circulation pump must be sized and integrated so that the required minimum flow rate is achieved.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eThe heating rod must not be operated dry. The housing of the heating cartridge must not be covered or thermally insulated. A functioning safety valve is required; no shut-off valves may be installed between the safety valve and the heating module.\u003c\/p\u003e \u003cp\u003eThe bundle does not replace proper system planning, heat load calculation, hydraulic design, or electrical testing. The suitability for the specific system must be professionally verified before installation and commissioning.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eMDC 230 heating module\u003c\/li\u003e \u003cli\u003eGEMA heating rod WEHP2230 2.0 kW 230 V\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Gema GmbH","offers":[{"title":"Default Title","offer_id":58079046402396,"sku":"MDC230+WEHP2230","price":205.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/durchlauferhitzer-notheizung-mdc-400p-inkl-elektroheizstab-9-kw-4897799.webp?v=1770692302","url":"https:\/\/hr.gemashop.de\/en\/products\/gema-mdc-230-bundle-module-heating-rod-wehp2230-2-0-kw-230-v","provider":"GEMA Shop","version":"1.0","type":"link"}