{"product_id":"gema-mdc-400-heizmodul-6-0-kw-400-v","title":"GEMA MDC 400 heating module with heating element 6.0 kW 400 V","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Application Area\u003c\/h2\u003e \u003cp\u003eThe GEMA MDC 400 heating module 6.0 kW is an electric auxiliary heating module for central heating systems and is integrated into the heating circuit as an additional heat source. It is suitable for supporting the heating of heating water when an existing primary heat source is to be supplemented, frost protection is to be supported, or electrical energy is to be specifically converted into heat.\u003c\/p\u003e \u003cp\u003eThe bundle combines the MDC 400 heating module with a 6.0 kW electric heating cartridge for operation at 400 V. This version is intended for applications where a higher electric auxiliary output is required in the heating circuit and a three-phase electrical connection can be professionally provided.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eThe MDC 400 is designed as an electric heating module for central heating systems. The steel tank is made of raw steel on the inside, powder-coated on the outside, and provided with 50 mm thick polyurethane foam thermal insulation. The outer casing is made of plastic, and the lid is made of ABS plastic.\u003c\/p\u003e \u003cp\u003eThe 6.0 kW heating cartridge included in the bundle operates with 3~400 V three-phase current. It features stepless temperature adjustment, indicator lights for power connection and heating operation, as well as a non-self-resetting safety temperature limiter. The heating module is intended for use with water or a suitable glycol mixture up to a maximum concentration of 50 percent.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThe bundle offers a compact way to introduce additional electric heat directly into the heating circuit. This allows an existing heating system to be flexibly supported without requiring a separate heat generator with fuel storage.\u003c\/p\u003e \u003cp\u003eThe 6.0 kW version is suitable for systems where a significantly higher auxiliary output is required than with 230 V heating modules. In conjunction with professional hydraulic integration and suitable control, the heating module can be used for auxiliary heating, frost protection, or surplus electricity concepts.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe MDC 400 is integrated into the parallel heating circuit on the flow or return line of the main heat source. For proper operation, an additional circulation pump is required to ensure the necessary minimum flow rate through the heating module.\u003c\/p\u003e \u003cp\u003eIntegration can be carried out in open or closed central heating systems, provided the appropriate safety devices are present. A safety valve with a suitable opening pressure as well as proper electrical protection and control connection must be taken into account on site.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical data at a glance\u003c\/h2\u003e \u003cp\u003eThe following information refers to the bundle consisting of the MDC 400 heating module and the 6.0 kW electric heating cartridge.\u003c\/p\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eNominal power\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e6.0 kW\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eEnergy source\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eElectricity\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eVoltage\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e400 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePhases\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e3-phase\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePower consumption\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e6,000 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMinimum flow rate\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e343 l\/h\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eControl current heating cartridge\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e8.7 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. operating pressure\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e10 bar \/ 1.0 MPa\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. operating temperature MDC\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e90 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. temperature setting heating cartridge\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eapprox. 70 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eConnection size heating module\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eFemale thread G 1 1\/4 inch\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eConnection thread heating cartridge\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e1 1\/2 inch\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eInstallation length heating cartridge\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e500 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eUnheated area\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e100 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eDevice length MDC 400\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e600 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating module material\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eSteel tank, raw steel inside, powder-coated outside\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eInsulation\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e50 mm polyurethane foam\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eThe installation of the heating module, the hydraulic connection, and the electrical test must be carried out by qualified professionals. The MDC 400 is integrated into the heating circuit and may only be operated after the system has been completely filled, vented, and checked for leaks.\u003c\/p\u003e \u003cp\u003eFor the 6.0 kW version, a minimum flow rate of 343 l\/h must be ensured in the central heating system. The additional circulation pump must be designed so that it works together with the heating cartridge and reliably dissipates the heat from the module.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eThe heating module must not be operated dry. The safety valve, venting, minimum flow rate, electrical protection, and control connection must be checked before commissioning. No shut-off valves may be installed between the safety valve and the heating module.\u003c\/p\u003e \u003cp\u003eWhen using photovoltaic surplus, a suitable external controller or switching logic is required. The heating module itself does not replace system planning, heat load calculation, or professional electrical sizing.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e1 x GEMA MDC 400 heating module\u003c\/li\u003e \u003cli\u003e1 x 6.0 kW electric heating cartridge according to bundle version\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Gema GmbH","offers":[{"title":"Zadani naziv","offer_id":54184730526044,"sku":"MDC400+EEHP6","price":373.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/durchlauferhitzer-mdc-400-plus-elektroheizstab-6-kw-4554019.jpg?v=1770693033","url":"https:\/\/hr.gemashop.de\/en\/products\/gema-mdc-400-modul-grijanja-6-0-kw-400-v","provider":"GEMA Shop","version":"1.0","type":"link"}