{"product_id":"gas-brennwertgerat-ecotec-plus-vc-vcw-vci-1-5","title":"Vaillant ecoTEC plus VC\/VCW\/VCI 1-5 Condensing Gas Boiler","description":"\u003ch2\u003eVaillant condensing gas boiler\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eVaillant ecoTEC plus VC\/VCW\/VCI 1-5 gas condensing boiler\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eThe ecoTEC plus VC\/VCW\/VCI 1-5 is the ideal gas condensing boiler for single-family homes and multi-family buildings. It can also be combined with a heat pump to create a sustainable hybrid system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"content-toggle-group content-toggle-group--theme-expand content-toggle--is-deactivated content-toggle-group--theme-expand--last-element\" data-content-toggle-theme-activated-only=\"default\" data-content-toggle-deactivate-at-breakpoint=\"640\"\u003e\n\u003cdiv class=\"content-toggle\"\u003e\n\u003ch2 class=\"content-toggle__trigger\" aria-selected=\"true\" aria-expanded=\"true\" role=\"tab\" id=\"benefitTrigger770\" aria-controls=\"benefitContent770\" tabindex=\"0\"\u003eHydrogen and bio-natural gas already taken into account\u003c\/h2\u003e\n\u003cdiv class=\"content-toggle__content\" aria-hidden=\"false\" role=\"tabpanel\" id=\"benefitContent770\" aria-labelledby=\"benefitTrigger770\"\u003e\n\u003cdiv class=\"content-toggle__content__inner\"\u003e\n\u003cp\u003eSince gas as a bridging technology will continue to play an important role in a future with sustainable energies, our ecoTEC plus is prepared for everything. The innovative gas condensing boiler is already suitable for operation with up to 20% hydrogen or up to 100% bio-natural gas. It can also be\u003cspan\u003e \u003c\/span\u003e\u003cb\u003econverted to operate with 100% hydrogen*\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eat a later date, thus meeting the current\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eH2 Ready\u003c\/b\u003erequirements of the Building Energy Act (GEG). The conversion kit required for this will be available from 2026. You can find more information on the topic of hydrogen\u003cspan\u003e \u003c\/span\u003e\u003ca class=\"link--internal\" data-scroll=\"\" href=\"https:\/\/www.vaillant.de\/heizung\/klima-foerderung\/heizen-mit-wasserstoff\/\" target=\"_self\" title=\"Heizen mit wasserstoff - vaillant\" aria-label=\"Besuchen Sie eine Webseite über Heizen mit wasserstoff - vaillant\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-toggle\"\u003e\n\u003ch2 class=\"content-toggle__trigger\" aria-selected=\"true\" aria-expanded=\"true\" role=\"tab\" id=\"benefitTrigger769\" aria-controls=\"benefitContent769\" tabindex=\"0\"\u003eTechnology that thinks ahead\u003c\/h2\u003e\n\u003cdiv class=\"content-toggle__content\" aria-hidden=\"false\" role=\"tabpanel\" id=\"benefitContent769\" aria-labelledby=\"benefitTrigger769\"\u003e\n\u003cdiv class=\"content-toggle__content__inner\"\u003e\n\u003cp\u003eOur innovative combustion control system IoniDetect ensures particularly reliable and efficient operation. The secret: the technology automatically detects different types of natural gas and gas qualities, thereby continuously optimizing the gas condensing system itself. This means you are perfectly prepared for the switch from L-gas to H-gas that is pending in some parts of Germany.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-toggle\"\u003e\n\u003ch2 class=\"content-toggle__trigger\" aria-selected=\"true\" aria-expanded=\"true\" role=\"tab\" id=\"benefitTrigger771\" aria-controls=\"benefitContent771\" tabindex=\"0\"\u003eAt home everywhere\u003c\/h2\u003e\n\u003cdiv class=\"content-toggle__content\" aria-hidden=\"false\" role=\"tabpanel\" id=\"benefitContent771\" aria-labelledby=\"benefitTrigger771\"\u003e\n\u003cdiv class=\"content-toggle__content__inner\"\u003e\n\u003cp\u003eThe Vaillant condensing gas boiler ecoTEC plus is not only ideal for single-family homes: it can be used as a central heating boiler in multi-family buildings as well as in larger buildings as a cascade system with up to 120 kW output.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-toggle\"\u003e\n\u003ch2 class=\"content-toggle__trigger\" aria-selected=\"true\" aria-expanded=\"true\" role=\"tab\" id=\"benefitTrigger2572\" aria-controls=\"benefitContent2572\" tabindex=\"0\"\u003eIntuitive operation, also convenient via app\u003c\/h2\u003e\n\u003cdiv class=\"content-toggle__content\" aria-hidden=\"false\" role=\"tabpanel\" id=\"benefitContent2572\" aria-labelledby=\"benefitTrigger2572\"\u003e\n\u003cdiv class=\"content-toggle__content__inner\"\u003e\n\u003cp\u003eThe modern design of the Vaillant condensing gas boiler ecoTEC plus is evident not only in its clean lines, but also in its large, illuminated touch display. This impresses with its intuitive and simple operation. The same applies to the controllers that match the ecoTEC plus: the premium system controller\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"noopener\" title=\"senso-comfort\" href=\"\/en\/products\/sensocomfort-vrc-720-3?_pos=4\u0026amp;_psq=senso\u0026amp;_ss=e\u0026amp;_v=1.0\" target=\"_blank\" aria-label=\"senso-comfort\"\u003esensoCOMFORT\u003c\/a\u003e, the single-zone controller\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"noopener\" title=\"senso-direct\" href=\"\/en\/products\/witterungsgefuhrter-einkreisregler-sensodirect?_pos=3\u0026amp;_psq=senso\u0026amp;_ss=e\u0026amp;_v=1.0\" target=\"_blank\" aria-label=\"senso-direct\"\u003esensoDIRECT\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003efor simple heating systems, or the room temperature controller\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"noopener\" title=\"senso-home\" href=\"\/en\/products\/raumtemperaturregler-sensohome?_pos=5\u0026amp;_psq=senso\u0026amp;_ss=e\u0026amp;_v=1.0\" target=\"_blank\" aria-label=\"senso-home\"\u003esensoHOME\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003efor central heating boilers.\u003c\/p\u003e\n\u003cp\u003eIn conjunction with the optionally available internet module\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"noopener\" title=\"sensonet-vr921\" href=\"\/en\/products\/internetmodul-sensonet-vr-921?_pos=2\u0026amp;_psq=senso\u0026amp;_ss=e\u0026amp;_v=1.0\" target=\"_blank\" aria-label=\"sensonet-vr921\"\u003esensoNET\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e, you can also conveniently control the ecoTEC plus via the free\u003cspan\u003e \u003c\/span\u003e\u003ca class=\"link--internal\" data-scroll=\"\" href=\"https:\/\/www.vaillant.de\/heizung\/produkte\/mobile-apps\/myvaillant-app\/\" target=\"_self\" title=\"Myvaillant app | vaillant\" aria-label=\"Besuchen Sie eine Webseite über Myvaillant app | vaillant\"\u003emyVAILLANT App\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e. The internet module is simply and space-savingly attached under the gas condensing boiler via plug-and-play.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-toggle\"\u003e\n\u003ch2 class=\"content-toggle__trigger\" aria-selected=\"true\" aria-expanded=\"true\" role=\"tab\" id=\"benefitTrigger2573\" aria-controls=\"benefitContent2573\" tabindex=\"0\"\u003eHot water exactly as you wish\u003c\/h2\u003e\n\u003cdiv class=\"content-toggle__content\" aria-hidden=\"false\" role=\"tabpanel\" id=\"benefitContent2573\" aria-labelledby=\"benefitTrigger2573\"\u003e\n\u003cdiv class=\"content-toggle__content__inner\"\u003e\n\u003cp\u003eThe ecoTEC plus is available in three different variants: as a pure heating appliance (VC), as a combi appliance with integrated instantaneous hot water generation (VCW), and as a combi appliance with an integrated 20-liter stratified storage tank (VCI). The combi appliances deliver hot water particularly efficiently and are the ideal solution if a separate storage tank cannot be installed due to lack of space.\u003c\/p\u003e\n\u003cp\u003eFor higher hot water demand, we recommend combining them with our wall-mounted storage tanks\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"noopener\" title=\"Warmwasserspeicher-hängend\" href=\"\/en\/products\/warmwasserspeicher-actostor-vih-ql-75-2-b\" target=\"_blank\" aria-label=\"Warmwasserspeicher-hängend\"\u003eactoSTOR\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"\/en\/products\/warmwasserspeicher-unistor-vih-q-75-2-b\" title=\"rohrschlangenspeicher-warmwasserspeicher\" rel=\"noopener\" target=\"_blank\" aria-label=\"rohrschlangenspeicher-warmwasserspeicher\"\u003euniSTOR\u003c\/a\u003e. These are perfectly matched to the gas condensing boiler both visually and technically.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eTechnical data: Vaillant condensing gas boiler\u003c\/h3\u003e\n\u003cstyle type=\"text\/css\"\u003e \ttable.tableizer-table { \t\tfont-size: 12px; \t\tborder: 1px solid #CCC;  \t\tfont-family: Arial, Helvetica, sans-serif; \t}  \t.tableizer-table td { \t\tpadding: 4px; \t\tmargin: 3px; \t\tborder: 1px solid #CCC; \t} \t.tableizer-table th { \t\tbackground-color: #104E8B;  \t\tcolor: #FFF; \t\tfont-weight: bold; \t} \u003c\/style\u003e\n\u003ctable class=\"tableizer-table\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"tableizer-firstrow\"\u003e\n\u003cth\u003eTechnical data\u003c\/th\u003e\n\u003cth\u003eUnit\u003c\/th\u003e\n\u003cth\u003eVC 10CS\/1 -5\u003c\/th\u003e\n\u003cth\u003eVC 15CS\/1 -5\u003c\/th\u003e\n\u003cth\u003eVC 20CS\/1 -5\u003c\/th\u003e\n\u003cth\u003eVC 25CS\/1 -5\u003c\/th\u003e\n\u003cth\u003eVC 30CS\/1 -5\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat output at 50\/30°C natural gas E, natural gas LL (min - max)\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003ctd\u003e3.4 - 10.9\u003c\/td\u003e\n\u003ctd\u003e3.4 - 16.4\u003c\/td\u003e\n\u003ctd\u003e3.4 - 21\u003c\/td\u003e\n\u003ctd\u003e3.4 - 26.4\u003c\/td\u003e\n\u003ctd\u003e4.5 - 33.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat output at 80\/60°C natural gas E, natural gas LL (min - max)\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003ctd\u003e3 - 9.9\u003c\/td\u003e\n\u003ctd\u003e3 - 14.8\u003c\/td\u003e\n\u003ctd\u003e3 - 19.7\u003c\/td\u003e\n\u003ctd\u003e3 - 24.7\u003c\/td\u003e\n\u003ctd\u003eApr 30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat output at 50\/30°C liquid gas (min - max)\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003ctd\u003e5.4 - 10.9\u003c\/td\u003e\n\u003ctd\u003e5.4 - 16.4\u003c\/td\u003e\n\u003ctd\u003e5.4 - 21\u003c\/td\u003e\n\u003ctd\u003e5.4 - 26.4\u003c\/td\u003e\n\u003ctd\u003e8.4 - 33.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat output at 80\/60°C liquid gas (min - max)\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003ctd\u003e4.8 - 9.9\u003c\/td\u003e\n\u003ctd\u003e4.8 - 14.8\u003c\/td\u003e\n\u003ctd\u003e4.8 - 19.7\u003c\/td\u003e\n\u003ctd\u003e4.8 - 24.7\u003c\/td\u003e\n\u003ctd\u003e7.8 - 30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat output in hot water operation natural gas E, natural gas LL, liquid gas (max)\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e27.5\u003c\/td\u003e\n\u003ctd\u003e34.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency at 30% according to EN 15502 natural gas E, natural gas LL, liquid gas\u003c\/td\u003e\n\u003ctd\u003e%\u003c\/td\u003e\n\u003ctd\u003e109\u003c\/td\u003e\n\u003ctd\u003e109\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003ctd\u003e109\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency in hot water operation natural gas E, natural gas LL, liquid gas\u003c\/td\u003e\n\u003ctd\u003e%\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeasonal space heating energy efficiency ηs\u003c\/td\u003e\n\u003ctd\u003e%\u003c\/td\u003e\n\u003ctd\u003e92\u003c\/td\u003e\n\u003ctd\u003e93\u003c\/td\u003e\n\u003ctd\u003e94\u003c\/td\u003e\n\u003ctd\u003e94\u003c\/td\u003e\n\u003ctd\u003e94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical power consumption at 30%\u003c\/td\u003e\n\u003ctd\u003eW\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e41\u003c\/td\u003e\n\u003ctd\u003e57\u003c\/td\u003e\n\u003ctd\u003e59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical power consumption in heating operation (max)\u003c\/td\u003e\n\u003ctd\u003eW\u003c\/td\u003e\n\u003ctd\u003e66\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e91\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical power consumption in standby\u003c\/td\u003e\n\u003ctd\u003eW\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded components in electrical power\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePump\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby heat loss at tK 70°C\u003c\/td\u003e\n\u003ctd\u003e%\u003c\/td\u003e\n\u003ctd\u003e0.91\u003c\/td\u003e\n\u003ctd\u003e0.61\u003c\/td\u003e\n\u003ctd\u003e0.45\u003c\/td\u003e\n\u003ctd\u003e0.36\u003c\/td\u003e\n\u003ctd\u003e0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating side content\u003c\/td\u003e\n\u003ctd\u003el\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e2.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax operating pressure heating side\u003c\/td\u003e\n\u003ctd\u003ebar\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax heating flow temperature\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection value for natural gas E 1) 2)\u003c\/td\u003e\n\u003ctd\u003em³\/h\u003c\/td\u003e\n\u003ctd\u003e2.2\u003c\/td\u003e\n\u003ctd\u003e2.2\u003c\/td\u003e\n\u003ctd\u003e2.6\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection value for natural gas LL 1) 2)\u003c\/td\u003e\n\u003ctd\u003em³\/h\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3.5\u003c\/td\u003e\n\u003ctd\u003e4.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection value for liquid gas 1) 2)\u003c\/td\u003e\n\u003ctd\u003ekg\/h\u003c\/td\u003e\n\u003ctd\u003e0.8\u003c\/td\u003e\n\u003ctd\u003e0.8\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e1.1\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondensate quantity at 50\/30°C\u003c\/td\u003e\n\u003ctd\u003el\/h\u003c\/td\u003e\n\u003ctd\u003e1.02\u003c\/td\u003e\n\u003ctd\u003e1.53\u003c\/td\u003e\n\u003ctd\u003e2.04\u003c\/td\u003e\n\u003ctd\u003e2.55\u003c\/td\u003e\n\u003ctd\u003e3.06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow rate at ΔT 20 K (residual head)\u003c\/td\u003e\n\u003ctd\u003el\/h (mbar)\u003c\/td\u003e\n\u003ctd\u003e430 (200)\u003c\/td\u003e\n\u003ctd\u003e645 (200)\u003c\/td\u003e\n\u003ctd\u003e849 (200)\u003c\/td\u003e\n\u003ctd\u003e1,075 (200)\u003c\/td\u003e\n\u003ctd\u003e1,290 (200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion vessel content\u003c\/td\u003e\n\u003ctd\u003el\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-charge pressure\u003c\/td\u003e\n\u003ctd\u003ebar\u003c\/td\u003e\n\u003ctd\u003e0.75\u003c\/td\u003e\n\u003ctd\u003e0.75\u003c\/td\u003e\n\u003ctd\u003e0.75\u003c\/td\u003e\n\u003ctd\u003e0.75\u003c\/td\u003e\n\u003ctd\u003e0.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e230V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e230V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e230V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e230V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e230V\/50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct dimensions (height \/ width \/ depth)\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003ctd\u003e720 \/ 440 \/ 348\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct weight\u003c\/td\u003e\n\u003ctd\u003ekg\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection heating (flow and return)\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eG 3\/4\u003c\/td\u003e\n\u003ctd\u003eG 3\/4\u003c\/td\u003e\n\u003ctd\u003eG 3\/4\u003c\/td\u003e\n\u003ctd\u003eG 3\/4\u003c\/td\u003e\n\u003ctd\u003eG 3\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection cylinder\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eG 1\/2\u003c\/td\u003e\n\u003ctd\u003eG 1\/2\u003c\/td\u003e\n\u003ctd\u003eG 1\/2\u003c\/td\u003e\n\u003ctd\u003eG 1\/2\u003c\/td\u003e\n\u003ctd\u003eG 1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas connection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eØ 20 mm\u003c\/td\u003e\n\u003ctd\u003eØ 20 mm\u003c\/td\u003e\n\u003ctd\u003eØ 20 mm\u003c\/td\u003e\n\u003ctd\u003eØ 20 mm\u003c\/td\u003e\n\u003ctd\u003eØ 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection air, flue gas\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eØ 60\/100\u003c\/td\u003e\n\u003ctd\u003eØ 60\/100\u003c\/td\u003e\n\u003ctd\u003eØ 60\/100\u003c\/td\u003e\n\u003ctd\u003eØ 60\/100\u003c\/td\u003e\n\u003ctd\u003eØ 80\/125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE PIN\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0063CU3910\u003c\/td\u003e\n\u003ctd\u003e0063CU3910\u003c\/td\u003e\n\u003ctd\u003e0063CU3910\u003c\/td\u003e\n\u003ctd\u003e0063CU3910\u003c\/td\u003e\n\u003ctd\u003e0063CU3910\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas appliance category\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eI2N, I3P\u003c\/td\u003e\n\u003ctd\u003eI2N, I3P\u003c\/td\u003e\n\u003ctd\u003eI2N, I3P\u003c\/td\u003e\n\u003ctd\u003eI2N, I3P\u003c\/td\u003e\n\u003ctd\u003eI2N, I3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Vaillant","offers":[{"title":"10kW \/ VC","offer_id":47862815097180,"sku":"0010043896","price":4324.06,"currency_code":"EUR","in_stock":true},{"title":"15kW \/ VC","offer_id":47862815129948,"sku":"0010043897","price":4410.36,"currency_code":"EUR","in_stock":true},{"title":"20kW \/ VC","offer_id":47862815162716,"sku":"0010043898","price":4499.44,"currency_code":"EUR","in_stock":true},{"title":"25kW \/ VC","offer_id":47862815195484,"sku":"0010043899","price":4717.66,"currency_code":"EUR","in_stock":true},{"title":"30kW \/ VC","offer_id":47862815228252,"sku":"0010043900-VC","price":5074.53,"currency_code":"EUR","in_stock":true},{"title":"20kW\/26kW \/ VCW","offer_id":47872721420636,"sku":"0010043901","price":5268.83,"currency_code":"EUR","in_stock":true},{"title":"25kW\/32kW \/ VCW","offer_id":47872721486172,"sku":"0010043902","price":5406.89,"currency_code":"EUR","in_stock":true},{"title":"20kW\/26kW \/ VCI","offer_id":47872721453404,"sku":"0010043903","price":6834.33,"currency_code":"EUR","in_stock":true},{"title":"25kW\/32kW \/ VCI","offer_id":47872721518940,"sku":"0010043904","price":7112.69,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/gastherme-vaillant-brennwert-ecotec-plus-vcvcwvci-1-5-6564511.png?v=1770692663","url":"https:\/\/hr.gemashop.de\/en\/products\/plin-kondenzacijski-uredaj-ecotec-plus-vc-vcw-vci-1-5","provider":"GEMA Shop","version":"1.0","type":"link"}