{"product_id":"schichten-pufferspeicher-schoenberg-spsrr-600-551-l-2-waermetauscher","title":"Layered buffer tank Schönberg SPSRR 600, 551 l, with 2 heat exchangers","description":"\u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Application Area\u003c\/h2\u003e \u003cp\u003eThe Schönberg SPSRR 600 is a stratified buffer tank for heating water with two integrated heat exchangers. It is suitable for heating systems in which multiple heat generators or separate heat exchanger circuits are to be integrated into a storage system.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eThe stratification technology supports an orderly temperature distribution in the tank. The SPSRR 600 features an upper heat exchanger with a surface area of 1.8 m² and a lower heat exchanger with a surface area of 2.4 m². Eight 1 1\/2\u0026quot; female threads are available for charging and discharging. Sensors and controllers can be connected via four 1\/2\u0026quot; female threads.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThanks to the two integrated heat exchangers, the tank can be flexibly integrated into systems with separate circuits. The multiple charging and discharging connections facilitate system-specific hydraulic planning. The selectable insulation variants allow adaptation to energy efficiency, installation dimensions, and installation situation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe tank is intended for heating water and is integrated into the heating system according to the system schematic. The two heat exchangers enable separate heat exchanger circuits, while the 1\/2\u0026quot; connections support the positioning of sensors and control components. Electric heating cartridges may only be mounted on the designated red-marked nozzles.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical Data at a Glance\u003c\/h2\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eModel\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eSPSRR 600\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eStorage tank type\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eStratified buffer storage tank\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eNet capacity without heat exchanger\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e551 l\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eNumber of heat exchangers\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eHeat exchanger surface area (top)\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1.8 m²\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eHeat exchanger surface area (bottom)\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e2.4 m²\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. operating pressure, tank\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e5 bar\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. operating pressure, heat exchanger\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e10 bar\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. operating temperature\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e95 °C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eDiameter without insulation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e700 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eHeight with insulation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1.690 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eTipping dimension without insulation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1.710 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eWeight without insulation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e200 kg\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eLoading \/ unloading connections\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e8 x 1 1\/2\u0026quot; IG\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eSensor \/ controller connections\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e4 x 1\/2\u0026quot; IG\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eVentilation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1 1\/4\u0026quot; female thread\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eConnection for electric heating cartridge\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e2 x 1 1\/2\u0026quot; female thread, at tank center and tank bottom\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eInsulation variants\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eEPS 100 mm, EPS 130 mm, STS vacuum plus 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eThe tank must be transported and set up in an upright position, dry, and secured against tipping over. The installation site must be load-bearing, level, frost-free, and sufficiently accessible for connection, testing, and maintenance work. Hydraulic connection, pressure testing, and commissioning must be carried out by qualified personnel or a specialized company.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eBefore installing electric heating cartridges, the installation length, electrical data, fuse protection, and suitability of the heating cartridge must be checked separately. The insulation should only be installed after the tank has been set up, connections have been made, and a leak test has been completed. The tank is intended for heating water and does not replace proper system planning.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eSchönberg SPSRR 600 stratified buffer tank\u003c\/li\u003e \u003cli\u003eInsulation depending on the selected version\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Schönberg","offers":[{"title":"100mm","offer_id":58216592965980,"sku":"SPSRR600+EKKC","price":1586.66,"currency_code":"EUR","in_stock":true},{"title":"130mm","offer_id":58216593064284,"sku":"SPSRR600+EKKB","price":1790.43,"currency_code":"EUR","in_stock":true},{"title":"150mm","offer_id":58216593162588,"sku":"SPSRR600+EKKA","price":1978.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/gema-shop-schichten-pufferspeicher-spsrr-1500_2f05201c-64b9-4f40-90d4-c47e142d1871.jpg?v=1783930945","url":"https:\/\/hr.gemashop.de\/en\/products\/schichten-pufferspeicher-schonberg-spsrr-600-551-l-2-warmetauscher-2","provider":"GEMA Shop","version":"1.0","type":"link"}