{"product_id":"viallant-warmepumpe-arotherm-plus","title":"Vaillant heat pump aroTHERM plus","description":"\u003cdiv class=\"base__image-text-section overflow-auto\"\u003e\n\u003cdiv class=\"base__image-text-section__container\"\u003e\n\u003ch2\u003eVaillant heat pump aroTHERM plus\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAs compact as it is effective: the Vaillant air-to-water heat pump\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOur aroTHERM plus is an outdoor air-to-water heat pump in monoblock design with a footprint of only 0.5 m². The heat is generated in the outdoor unit and routed via supply lines to the indoor unit in the heating room. The aroTHERM plus is perfectly complemented by an indoor hydraulic unit, such as our hydraulic tower uniTOWER plus. With its integrated 185-liter storage tank, it easily covers the hot water needs of a family of four. For higher hot water demand, our wall-mounted hydraulic station and a suitable hot water storage tank are ideal.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-toggle-group content-toggle-group--theme-expand content-toggle--is-deactivated\" data-content-toggle-theme-activated-only=\"default\" data-content-toggle-deactivate-at-breakpoint=\"640\"\u003e\n\u003ch3 class=\"content-toggle\"\u003eModernize with future-proof technology\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-toggle\"\u003e\n\u003cdiv class=\"content-toggle__content\" aria-hidden=\"false\" role=\"tabpanel\" id=\"benefitContent1\" aria-labelledby=\"benefitTrigger1\"\u003e\n\u003cdiv class=\"content-toggle__content__inner\"\u003e\n\u003cp\u003eBecause the aroTHERM plus uses the natural refrigerant R290, it is ideal for climate-conscious modernization with a capacity of 7–12 kW. Replacing old oil or gas heating systems in single-family homes is no problem. The refrigerant enables high flow temperatures in heat pump operation, so existing radiators can also be operated. Another plus: R290 has a very low global warming potential. With a COP of up to 3.3 and 3.8, our aroTHERM plus also operates very efficiently and environmentally friendly. Alternatively, it can also be installed in new buildings.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"content-toggle\"\u003eThe quietest heat pump in its class\u003c\/h3\u003e\n\u003cdiv class=\"content-toggle__content\" aria-hidden=\"false\" role=\"tabpanel\" aria-labelledby=\"benefitTrigger2\"\u003e\n\u003cdiv class=\"content-toggle__content\" aria-hidden=\"false\" role=\"tabpanel\" aria-labelledby=\"benefitTrigger2\"\u003e\n\u003cdiv class=\"content-toggle__content__inner\"\u003e\n\u003cp\u003eThe integrated Sound Safe System ensures that the aroTHERM plus operates particularly quietly. It is therefore perfect for use even in densely built-up areas, for example in terraced housing estates. The sound power level is only 46 dB(A) in night mode, and even only 29 dB(A) at a distance of 3 m. This means the aroTHERM plus easily complies with the TA-Lärm directive in densely built-up residential areas.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant notes!\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eRequires multiMATIC 700 or sensoCOMFORT 720. Accessory coding resistor is additionally required for active cooling operation.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct features:\u003cbr\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModulating EC fan\u003c\/li\u003e\n\u003cli\u003eHigh-efficiency pump\u003c\/li\u003e\n\u003cli\u003eSensor-controlled refrigerant circuit\u003c\/li\u003e\n\u003cli\u003eIntegrated R290 safety concept\u003c\/li\u003e\n\u003cli\u003eAutomatic air vent valve\u003c\/li\u003e\n\u003cli\u003eCooling operation can be activated with coding plug (the heating system must be prepared on site for this)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cbr\u003eSpecial features:\u003cbr\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh flow temperatures for modernization\u003c\/li\u003e\n\u003cli\u003eModulating compressor with inverter technology always adapts the output to the current building heating load\u003c\/li\u003e\n\u003cli\u003eSoundSafeSystem for particularly quiet operation\u003c\/li\u003e\n\u003cli\u003eCan also be integrated into an existing heating system\u003c\/li\u003e\n\u003cli\u003eCan be operated in a hybrid system bivalent alternative, parallel, or with the triVAI parameter\u003c\/li\u003e\n\u003cli\u003eIntelligent use of self-generated energy (PV ready)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eScope of delivery: \u003c\/strong\u003eVaillant heat pump aroTHERM plus\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e1 aroTHERM VWL\u003cbr\u003e1 condensate drain\u003cbr\u003e1 bag with seals\u003cbr\u003e1 vent hose\u003cbr\u003e1 operating and installation instructions\u003cbr\u003e1 product data sheet, energy efficiency label\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eTechnical data: Vaillant heat pump aroTHERM plus\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle type=\"text\/css\"\u003e\n\ttable.tableizer-table {\n\t\tfont-size: 12px;\n\t\tborder: 1px solid #CCC; \n\t\tfont-family: Arial, Helvetica, sans-serif;\n\t} \n\t.tableizer-table td {\n\t\tpadding: 4px;\n\t\tmargin: 3px;\n\t\tborder: 1px solid #CCC;\n\t}\n\t.tableizer-table th {\n\t\tbackground-color: #104E8B; \n\t\tcolor: #FFF;\n\t\tfont-weight: bold;\n\t}\n\u003c\/style\u003e\n\u003cdiv class=\"content-toggle__content\" aria-hidden=\"false\" role=\"tabpanel\" id=\"benefitContent2\" aria-labelledby=\"benefitTrigger2\"\u003e\n\u003ctable class=\"tableizer-table\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"tableizer-firstrow\"\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eVWL 35\/6 A\u003c\/th\u003e\n\u003cth\u003eVWL 55\/6 A\u003c\/th\u003e\n\u003cth\u003eVWL 75\/6 A\u003c\/th\u003e\n\u003cth\u003eVWL 105\/6 A\u003c\/th\u003e\n\u003cth\u003eVWL 125\/6 A\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy efficiency class 55°C (A+++ - D)\u003c\/td\u003e\n\u003ctd\u003eA+\u003c\/td\u003e\n\u003ctd\u003eA++\u003c\/td\u003e\n\u003ctd\u003eA++\u003c\/td\u003e\n\u003ctd\u003eA++\u003c\/td\u003e\n\u003ctd\u003eA++\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy efficiency class 35°C (A+++ - D)\u003c\/td\u003e\n\u003ctd\u003eA++\u003c\/td\u003e\n\u003ctd\u003eA+++\u003c\/td\u003e\n\u003ctd\u003eA+++\u003c\/td\u003e\n\u003ctd\u003eA+++\u003c\/td\u003e\n\u003ctd\u003eA+++\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating output \/ Electrical input \/ COP at A-7\/W35\u003c\/td\u003e\n\u003ctd\u003e3.6 kW \/ 1.55 kW \/ 2.2\u003c\/td\u003e\n\u003ctd\u003e5.4 kW \/ 2.08 kW \/ 2.6\u003c\/td\u003e\n\u003ctd\u003e7.0 kW \/ 2.5 kW \/ 2.8\u003c\/td\u003e\n\u003ctd\u003e9.2 kW \/ 3.41 kW \/ 2.7\u003c\/td\u003e\n\u003ctd\u003e12.2 kW \/ 4.52 kW \/ 2.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating output \/ Electrical input \/ COP at A2\/W35\u003c\/td\u003e\n\u003ctd\u003e2.0 kW \/ 0.51 kW \/ 3.9\u003c\/td\u003e\n\u003ctd\u003e2.0 kW \/ 0.51 kW \/ 3.9\u003c\/td\u003e\n\u003ctd\u003e3.1 kW \/ 0.76 kW \/ 4.1\u003c\/td\u003e\n\u003ctd\u003e5.8 kW \/ 1.26 kW \/ 4.6\u003c\/td\u003e\n\u003ctd\u003e5.9 kW \/ 1.28 kW \/ 4.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating output \/ Electrical input \/ COP at A7\/W35\u003c\/td\u003e\n\u003ctd\u003e3.3 kW \/ 0.69 kW \/ 4.8\u003c\/td\u003e\n\u003ctd\u003e3.4 kW \/ 0.71 kW \/ 4.8\u003c\/td\u003e\n\u003ctd\u003e4.6 kW \/ 0.96 kW \/ 4.8\u003c\/td\u003e\n\u003ctd\u003e8.1 kW \/ 1.53 kW \/ 5.3\u003c\/td\u003e\n\u003ctd\u003e8.5 kW \/ 1.57 kW \/ 5.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating output \/ Electrical input \/ COP at A10\/W35\u003c\/td\u003e\n\u003ctd\u003e3.4 kW \/ 0.64 kW \/ 5.3\u003c\/td\u003e\n\u003ctd\u003e3.5 kW \/ 0.66 kW \/ 5.3\u003c\/td\u003e\n\u003ctd\u003e4.8 kW \/ 0.92 kW \/ 5.2\u003c\/td\u003e\n\u003ctd\u003e8.7 kW \/ 1.53 kW \/ 5.3\u003c\/td\u003e\n\u003ctd\u003e8.8 kW \/ 1.54 kW \/ 5.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling output \/ Electrical input \/ EER at A35\/W18\u003c\/td\u003e\n\u003ctd\u003e4.5 kW \/ 1.05 kW \/ 4.3\u003c\/td\u003e\n\u003ctd\u003e4.5 kW \/ 1.05 kW \/ 4.3\u003c\/td\u003e\n\u003ctd\u003e6.4 kW \/ 1.52 kW \/ 4.2\u003c\/td\u003e\n\u003ctd\u003e10.9 kW \/ 2.37 kW \/ 4.6\u003c\/td\u003e\n\u003ctd\u003e10.8 kW \/ 2.35 kW \/ 4.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeasonal space heating energy efficiency ηS at 35°C\u003c\/td\u003e\n\u003ctd\u003e174%\u003c\/td\u003e\n\u003ctd\u003e181%\u003c\/td\u003e\n\u003ctd\u003e182%\u003c\/td\u003e\n\u003ctd\u003e196%\u003c\/td\u003e\n\u003ctd\u003e193%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeasonal space heating energy efficiency ηS at 55°C\u003c\/td\u003e\n\u003ctd\u003e123%\u003c\/td\u003e\n\u003ctd\u003e129%\u003c\/td\u003e\n\u003ctd\u003e133%\u003c\/td\u003e\n\u003ctd\u003e141%\u003c\/td\u003e\n\u003ctd\u003e146%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor power supply\u003c\/td\u003e\n\u003ctd\u003e230 V\/50 Hz\u003c\/td\u003e\n\u003ctd\u003e230 V\/50 Hz, 1\/N\/PE~\u003c\/td\u003e\n\u003ctd\u003e230 V\/50 Hz, 1\/N\/PE~\u003c\/td\u003e\n\u003ctd\u003e400 V\/50 Hz, 3\/N\/PE~\u003c\/td\u003e\n\u003ctd\u003e400 V\/50 Hz, 3\/N\/PE~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical power consumption of pump at min.\u003c\/td\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical power consumption of pump (max.)\u003c\/td\u003e\n\u003ctd\u003e50 W\u003c\/td\u003e\n\u003ctd\u003e50 W\u003c\/td\u003e\n\u003ctd\u003e50 W\u003c\/td\u003e\n\u003ctd\u003e87 W\u003c\/td\u003e\n\u003ctd\u003e87 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating side content\u003c\/td\u003e\n\u003ctd\u003e1.5 l\u003c\/td\u003e\n\u003ctd\u003e1.5 l\u003c\/td\u003e\n\u003ctd\u003e2.0 l\u003c\/td\u003e\n\u003ctd\u003e2.5 l\u003c\/td\u003e\n\u003ctd\u003e2.5 l\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. operating pressure heating side\u003c\/td\u003e\n\u003ctd\u003e3 bar\u003c\/td\u003e\n\u003ctd\u003e3 bar\u003c\/td\u003e\n\u003ctd\u003e3 bar\u003c\/td\u003e\n\u003ctd\u003e3 bar\u003c\/td\u003e\n\u003ctd\u003e3 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating temperature (min.-max.)\u003c\/td\u003e\n\u003ctd\u003e22-75 °C\u003c\/td\u003e\n\u003ctd\u003e22-75 °C\u003c\/td\u003e\n\u003ctd\u003e22-75 °C\u003c\/td\u003e\n\u003ctd\u003e22-75 °C\u003c\/td\u003e\n\u003ctd\u003e22-75 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot water temperature with auxiliary heating (max.)\u003c\/td\u003e\n\u003ctd\u003e75 °C\u003c\/td\u003e\n\u003ctd\u003e75 °C\u003c\/td\u003e\n\u003ctd\u003e75 °C\u003c\/td\u003e\n\u003ctd\u003e75 °C\u003c\/td\u003e\n\u003ctd\u003e75 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. power consumption\u003c\/td\u003e\n\u003ctd\u003e3.4 kW\u003c\/td\u003e\n\u003ctd\u003e3.4 kW\u003c\/td\u003e\n\u003ctd\u003e3.4 kW\u003c\/td\u003e\n\u003ctd\u003e8.0 kW\u003c\/td\u003e\n\u003ctd\u003e8.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarting current\u003c\/td\u003e\n\u003ctd\u003e14.3 A\u003c\/td\u003e\n\u003ctd\u003e14.3 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow rate at 5K (residual head)\u003c\/td\u003e\n\u003ctd\u003e580 l\/h (780 mbar)\u003c\/td\u003e\n\u003ctd\u003e580 l\/h (780 mbar)\u003c\/td\u003e\n\u003ctd\u003e790 l\/h (640 mbar)\u003c\/td\u003e\n\u003ctd\u003e1418 l\/h (788 mbar)\u003c\/td\u003e\n\u003ctd\u003e1480 l\/h (730 mbar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating connection (flow and return)\u003c\/td\u003e\n\u003ctd\u003eG 1 1\/4\u003c\/td\u003e\n\u003ctd\u003eG 1 1\/4\u003c\/td\u003e\n\u003ctd\u003eG 1 1\/4\u003c\/td\u003e\n\u003ctd\u003eG 1 1\/4\u003c\/td\u003e\n\u003ctd\u003eG 1 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound power level (A7\/W55)\u003c\/td\u003e\n\u003ctd\u003e54 dB(A)\u003c\/td\u003e\n\u003ctd\u003e54 dB(A)\u003c\/td\u003e\n\u003ctd\u003e55 dB(A)\u003c\/td\u003e\n\u003ctd\u003e59 dB(A)\u003c\/td\u003e\n\u003ctd\u003e59 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct dimensions (height\/width\/depth)\u003c\/td\u003e\n\u003ctd\u003e765 \/ 1,100 \/ 450 mm\u003c\/td\u003e\n\u003ctd\u003e765\/1100\/450 mm\u003c\/td\u003e\n\u003ctd\u003e965\/1100\/450 mm\u003c\/td\u003e\n\u003ctd\u003e1,565 \/ 1,100 \/ 450 mm\u003c\/td\u003e\n\u003ctd\u003e1565\/1100\/450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct weight\u003c\/td\u003e\n\u003ctd\u003e114 kg\u003c\/td\u003e\n\u003ctd\u003e114 kg\u003c\/td\u003e\n\u003ctd\u003e128 kg\u003c\/td\u003e\n\u003ctd\u003e210 kg\u003c\/td\u003e\n\u003ctd\u003e210 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant charge\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant (natural)\u003c\/td\u003e\n\u003ctd\u003eR290\u003c\/td\u003e\n\u003ctd\u003eR290\u003c\/td\u003e\n\u003ctd\u003eR290\u003c\/td\u003e\n\u003ctd\u003eR290\u003c\/td\u003e\n\u003ctd\u003eR290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal warming potential according to Regulation (EU)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO2 equivalent\u003c\/td\u003e\n\u003ctd\u003e0.0018 t\u003c\/td\u003e\n\u003ctd\u003e0.0018 t\u003c\/td\u003e\n\u003ctd\u003e0.0027 t\u003c\/td\u003e\n\u003ctd\u003e0.0039 t\u003c\/td\u003e\n\u003ctd\u003e0.0039 t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Vaillant","offers":[{"title":"VWL 35\/6 A S2","offer_id":47229499736412,"sku":"10021116","price":5386.59,"currency_code":"EUR","in_stock":true},{"title":"VWL 55\/6 A S2","offer_id":47229499769180,"sku":"10021117","price":5905.76,"currency_code":"EUR","in_stock":true},{"title":"VWL 75\/6 A S2","offer_id":47229499801948,"sku":"10021118","price":6858.71,"currency_code":"EUR","in_stock":true},{"title":"VWL 105\/6 A S2","offer_id":47229499834716,"sku":"10021120","price":9547.48,"currency_code":"EUR","in_stock":true},{"title":"VWL 125\/6 A S2","offer_id":47229499867484,"sku":"10021122","price":10827.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/vaillant-warmepumpe-arotherm-plus-3176332.jpg?v=1770693549","url":"https:\/\/hr.gemashop.de\/en\/products\/vaillant-dizalica-topline-arotherm-plus","provider":"GEMA Shop","version":"1.0","type":"link"}